Selectable High Impedance Adapter
Advantages:
- Improves accuracy of P/S readings.
- Compensates for high resistance contacts between soil and electrode.
- Detects high contact resistance at the test lead / structure connection.
- Operates with any voltmeter.
- Switch-selectable input impedance of 20, 50, 100, 200 MOhm, and 1GOhm / Open.
- Superior filtering of AC noise.
- Watertight enclosure - small and convenient.
- Has a bypassswitch which allows voltages to be measured directly by bypassing
the high impedance buffer, including voltages larger than 4V
When structure-to-soil readings are
taken across highly resistive materials such as dry soil, sand,
rock, and concrete, readings can appear lower than their actual
values. Relying on such low readings can lead to over
compensation of the rectifiers' output, overprotection of the
structure, and wasted resources.
No longer is it necessary to rely on the fixed 10 MOhm input
impedance of standard voltmeters and data loggers for dependable
readings. The solution to this common difficulty is the
Selectable High Impedance Adapter. The adapter enables any
standard impedance voltmeter or data logger to vary its input
impedance, thereby eliminating contact resistance errors from
readings.
General Information:
Due to the limitations of standard voltmeters, an error can be realized while performing
readings with high impedance sources (e.g., structure-to-soil
readings at the point where a copper / copper sulfate reference
electrode makes contact with the earth). This error is a result of a
current loop created by the voltmeter, which causes a drop across
the source resistance. The Selectable High Impedance Adapter varies
this current loop, allowing the user to determine when the error has
been made insignificant. However, with higher impedance there is an
increase in noise pickup. Therefore, when two adjacent ranges give
the same readings, select the lower of the two ranges to limit
pickup while maintaining the most precise reading.
Specifications
The Selectable High Impedance Adapter is a multipurpose device used to vary the input
impedance of data loggers and voltmeters, as well as a filter to
remove AC noise.
The high impedance adapter has excellent AC noise rejection capabilities that improve
as the frequency of the noise increases. Noise at a frequency of 50
Hz and 6.36 Vrms (9 V peak) produces only 1 count of error (+1.5
mV) at the output, while at 60 Hz, it takes 19.1 VRMS (27 Vpeak of
noise) to cause 1 count of error.
The selectable input
impedance feature permits detection of high resistance in the
external circuit and the elimination of resulting errors in
virtually all cases. This feature is implemented by first taking the
reading with the High Impedance Adapter in the 20 MOhm position and
switching to the next higher impedance while watching the output
until the reading is constant. Next, turn the switch back one
position to decrease the impedance, which will reduce any noise
pickup and will result in the most precise reading.
In addition to giving precise readings, the High Impedance Adapter can also withstand a
constant DC input of 700 volts as well as 1.5 kV voltage spikes.
The OFF position of the
adapter functions as a means of testing its internal battery from a
digital multimeter. To test the battery, turn the switch to the OFF
/ BAT TEST position and connect the High Impedance Adapter's output
to a digital multimeter and set it to the 200 mV range. A reading
below 80 mV requires that the battery be changed.
Frequency Response
| Frequency |
Attenuation |
Counts of Error |
50 Hz
60 Hz |
-74.3 dB
-85.6 dB |
1 in 5,210
1 in 19,149 |
AC Rejection at 50 Hz
| Rejection |
Counts of Ripple |
Settling Time |
6.36 Vrms
11.3 Vrms
17.7 Vrms |
1 (+1.5 mV)
2 (+2.5 mV)
3 (+3.5 mV) |
<200 ms
<200 ms
<200 ms |
AC Rejection at 60 Hz
| Rejection |
Counts of Ripple |
Settling Time |
19.1 Vrms
33.2 Vrms |
1 (+1.5 mV)
2 (+2.5 mV) |
<200 ms
<200 ms |
Maximum AC noise before distortion occurs
| Frequency |
AC Noise |
50 Hz
60 Hz |
25.5 Vrms
34.0 Vrms |
DC Response and Accuracy:
It takes the High Impedance Adapter less than 200ms to reach an output
voltage of 2VDC +1mV with a 2VDC
input. Maximum operational DC input: +4V.
Input Impedance: Switch selectable (20, 50, 100, 200MΩ,
1GΩ).
Definitions:
Rejection is defined as the 60 Hz (50 Hz) RMS
voltage required to cause the corresponding counts of ripple.
Settling Time is defined as the time for the output to be
within the corresponding counts of ripple for each rejection.
Counts of Ripple refers to the amount of amplitude variation due to AC
noise.
Selectable Bypass Polarity Switch:
1. In the ON position, the HIB will work in normal working
capabilities.
2. In the OFF position, The HIB is completely turned off.
3. In the BYPASS position the HIB is being bypassed thru that is
higher then 4V. Switch capacity is at 5A.
Battery:
9V alkaline or 9V lithium recommended.
Battery Life:
Alkaline - greater than 60 hours of continuous operation (worst case).
Lithium - greater than 210 hours of continuous operation (worst case).
Minimum battery voltage:
8.0 Volts
Operating temperature:
-40oF to 185oF (-40oC
to +85oC).
Size:
Overall: 3-1 /4" x 3-9/16" x 3" (8.3 x 9.0 x 7.6 cm)
Box: 3-1/4"x 3-3/16 x 2-3/16" box (8.3 x 8.1 x 5.6 cm)
Weight:
9.3 oz. (264 g)
Options:
Mounting plate for attaching the Selectable High Impedance
Adapter to the M. C. Miller Co., Inc. SinCorder.